8077-F
Software is not bundled with this product. Please confirm that the program you select will operate properly according to the communication
protocol and conditions listed below. ID data is stored in ROM and therefore will not be cleared when the unit is turned off.
٨
Do not use excessive force when inserting a wire into the wire insert point. Damage may result to the terminal or product.
Caution
3.How to use (ASCII command requirements)
Communication protocol
@ ޓ? ޓ? ޓ1 ޓ2 ޓ> ޓ!
Header ID1 ID2
Command
Data1 Data2
End code
Header
㧬㨇40H
End code
!21H
ID
Command
030H㨉̖ActionOFF
131H㨉̖ActionON
? [3FH] --- Create or change ID
Data
٨Command to operate 1-8 outputs
٨Command to set ID # when ID is used (optional)
This example operates switches # 6,4,3 and2.
Programming example as above executes the commands set on No.6,4,3 and 2.
Example input
Letter
(
ASCII code
)
Bit data
Action No.
Data1
232H
00110010
8765
Data2
>3EH
00111110
4321
1 bite
2 bite
1 bite
2 bite
1 bite
The default ID is ?? [3FH 3FH].
In this case, the unit does not use an ID.
Examples
Serial communication specification
Reply code
Header ID1 ID2
command
Data1 Data2
End code
??108
40H 3FH 3FH 31H
30H 38H
21H
ASCII code
HEX code
٨To excute the command of No.4 on
00110000B 00111000B
Header ID1 ID2
command
Data1 Data2
End code
??0??
40H 3FH 3FH 30H
3FH 3FH
21H
ASCII code
HEX code
٨To cancel all the commands
00111111B 00111111B
Header ID1 ID2
command
Data1 Data2
End code
23?46
40H 32H 33H 3FH 34H 36H 21H
ASCII code
HEX code
٨
To change ID of PHC-100A from 23[32H*33H] to 46[34H*36H]
Communication specification
RS-232C compliant
Communication speed
9600bps
Data length 8 bit
Stop bit 1 bit
Parity Any setting
Any setting
synchronous mode
Flow control
Synchronous mode
Transmission mode Half-duplex mode
Transmission code ASCII code
Reply code
ACK06H
NACK15H
̪The product d
oes not work if a command is sent before ACK(06H) is replied.
Reply code
E㨞㨞㨛㨞 contents
When a command, other than 0[30H], 1[31H] or ?[3FH], is set
When data, other than 0[30H] - ?[3FH], is used
Reply interval between data is
more than 5 seconds after receipt of header
Transmission condition
ACK06H
When data transmission is finished
NACK15H
Command error
Data error
Timeout
Connect the (straight) cable DSUB9P (female) connector to the PHC-100A communications port.
Connect the other end of the cable to your PC or DTE device
̪
عPHC-100A ع㧼㧯
Refer to instructions manual of PC
when connecting this product to
PC with RS-232C straight cable.
AC adaptor
120V AC
ASCII code
Hex 0 1 2 3 4
0 NUL DLE Space 0 @
1 SOH DC1 ! 1 A
2 STX DC2 " 2 B
3 ETX DC3 # 3 C
4 EOT DC4 $ 4 D
5ENQNAK% 5 E
6 ACK SYN & 6 F
7 Bell ETB ' 7 G
8 BS CAN ( 8 H
9HTEM) 9 I
A LF SUB * : J
B VT ESC + ; K
CFFFS , < L
DCRGS - = M
ESORS . > N
FSIUS/ ?O
Higher code
Lower code
Connection cable
Signal
PHC-100A
Shield
Pin No.
FG -
TXD 3
RXD 2
RTS 7
CTS 8
SG 5
Signal
PC
Data output
Pin No.
-1
32
23
74
85
57
FG
TXD
RXD
RTS
CTS
SG
D-SUB9P D-SUB25P
D-SUB9P
عReset switch
All commands can be reset by pressing a reset switch.
While the reset switch is pressed, this product does not
accept any communication commands, and then, CTS line of
RS-232C will be at low level.
3.Wiring example
The internal contacts are non-voltage contacts (relay contact). They operate products which contact capacity is under AC125V3A or DC30V3A.
The products having the different voltage can be connected to each contact, since each contact is independent.
̪The example listed above is in the case of the 120V AC product. The direct current product of DC 30V or less also can be connected.
RS-232C Straight cable
Power operatingIn the case of products operated by power supply(When the 120V AC product is used)
عWiring example 1
AC adaptor connection
٨Block diagram٨Wiring diagram
ψ120V AC
120V AC φ
120V AC
PC
RS-232C Straight
cable
< Warning lights etc. >
PHC-100A
AC adaptor
(bundled)
PC
PHC-100A
PC
PHC-100A
RS-232C straight
cable
RS-232C Straight
cable
120V ACޓ
φ
AC adaptor connection
Signal light
Audible alarms
etc.
lead wire 1
lead wire 2
lead wire 3
COM wire
ψ 120V AC
1.Wiring to the terminal block
2.Connecting the RS-232C cable (Not supplied with the PHC-100A)
٨Terminal block
٨How to make wiring connection
Ԙ Strip the wire insulation back 9 mm ԙ Depress the connect-disconnect lever with a slotted screwdriver
Ԛ While holding the lever depressed, insert the wire
ԛ Remove the screwdriver to and check that the wire does not come out easily
Connect-disconnect lever operation A slotted screwdriverޓnominal size 4.5mm50mm
Applecable wire
9mm
A solid wireޓǾ0.4㨪Ǿ1.2mm AWG2618
A twisted wireޓ0.30.75mmޓ㧔AWG2220
̪When using stranded wire, the strand should be more than 0.18 mm diameter.
2
A slotted screwdriver
9mm
Connect-disconnect lever
Wire insert point
120V AC
120V AC
Warning
lights
RELAY
No.8
Lead wire operating : In the case of products operated by lead wire. (When the 120V AC product is used)
عWiring example 2
٨Block diagram
٨Wiring diagram
AC adaptor
(bundled)
PC
PHC-100A
120V AC
Signal
light
RELAY
No.8
RELAY
No.7
RELAY
No.6
ធὐኈ㊂
ޓޓޓޓޓޓޓ
߹ߢ
Contact capacity
125V AC,3A
30V DC,3A
87654321
࡝࡟࡯ធὐNo.(Relay contact No.)
㔚✢ⵍⷒ೸߈㐳ߐ㧦9mm(Strip)
න✢:
Ǿ
0.41.2mm(Single wire)
᠐✢:0.30.75mm
2
(Twist wire)
MODEL
PHC-100A
Reset switch
RS-232C
Power
24V DC
૶↪น⢻㔚✢
Applicable wire
Strip length
㧙㧞㧙 㧙㧟㧙
Zobrazit stránku 1
1 2

Komentáře k této Příručce

Žádné komentáře

HP Almacenamiento SAN de HP MSA 1040 podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Przechowywanie HP Almacenamiento SAN de HP MSA 1040.
Dostarczamy 1 pdf podręczników HP Almacenamiento SAN de HP MSA 1040 do pobrania za darmo według typów dokumentów: Instrukcja Użytkownika


Spis treści

HP MSA 1040

1

Guía de usuario

1

Contenido

3

4Contenido

4

Contenido 5

5

6Contenido

6

Figuras 7

7

8Figuras

8

Tablas 9

9

10 Tablas

10

1 Información general

11

12 Información general

12

2Componentes

13

PORT 1 PORT 2

14

Receptáculos de unidades

16

6Gb/s 6Gb/s

17

CompactFlash transportable

18

Paquete de supercondensador

19

Actualización a MSA 2040

19

20 Componentes

20

Encendido y apagado

27

Conector de cable de

28

Encendido

30

4Conexión de los host

31

Protocolo iSCSI de 10GbE

32

Protocolo iSCSI de 1 Gb

33

Un servidor/un HBA/ruta única

34

Un servidor/un HBA/ruta dual

34

Servidor 1 Servidor 2

35

Conmutador A

35

Conmutador B

35

MSA 1040

35

Cableado para réplica

36

Puertos de host y réplica

37

Varios servidores/una red

38

Actualización del firmware

39

40 Conexión de los host

40

Descripción del dispositivo

41

Host Interface

43

Not Shown

43

Problema

45

Solución

45

6 Funcionamiento básico

47

48 Funcionamiento básico

48

Conexión a puerto CLI de USB

49

Aislamiento del fallo

51

Detención de E/S

52

Pasos de diagnóstico

52

Fallo/UID) están apagados?

54

Transporte de la caché

57

Cableado para la réplica

60

¿Puede replicar un volumen?

63

¿Puede ver sistemas remotos?

64

Ubicación de los sensores

65

Sensores de temperatura

66

8 Asistencia y otros recursos

69

Convenciones tipográficas

70

Estabilidad del bastidor

71

Garantías del producto

71

Requisitos de seguridad

85

Directrices eléctricas

86

Requisitos de ventilación

86

Requisitos físicos

87

Requisitos del entorno

88

Requisitos eléctricos

88

C Descarga electrostática

89

90 Descarga electrostática

90

Índice 91

91

92 Índice

92

HP MSA 1040 User Guide 93

93

94 Índice

94





Więcej produktów i instrukcji dla Przechowywanie HP

Modele Rodzaj dokumentu
Unidades de cinta HP StoreEver DAT Instrukcja Użytkownika   HP Unidades de cinta HP StoreEver DAT Manual del usuario, 66 strony
Unidades de cinta HP StoreEver DAT Instrukcja Użytkownika   HP Unidades de cinta HP StoreEver DAT Manual del usuario, 58 strony
Soluciones HP LeftHand P4000 SAN Instrukcja Użytkownika   HP Soluciones HP LeftHand P4000 SAN Manual del usuario, 307 strony
Servidor de almacenamiento HP ProLiant DL380 G5 Instrukcja Użytkownika   HP Servidor de almacenamiento HP ProLiant DL380 G5 Manual del usuario [de] [en] , 160 strony
Sistemi di archiviazione di rete HP StorageWorks X Instrukcja Użytkownika   HP Sistemi di archiviazione di rete HP StorageWorks X3000 Manuale d'uso, 150 strony
Smart array modulare HP StorageWorks 2000fc G2 Instrukcja Użytkownika   HP Smart array modulare HP StorageWorks 2000fc G2 Manuale d'uso, 78 strony
Caricatore automatico nastro HP StorageWorks DAT 7 Instrukcja Użytkownika   HP Caricatore automatico nastro HP StorageWorks DAT 72x10 Manuale d'uso, 56 strony
Systèmes de stockage réseau HP StorageWorks X3000 Instrukcja Użytkownika   HP Systèmes de stockage réseau HP StorageWorks X3000 Manuel d&#039;utilisation [en] [de] [es] [fr] [it] , 136 strony
StoreEver Ultrium-Bandlaufwerke Instrukcja Użytkownika   HP StoreEver Ultrium-Bandlaufwerke Benutzerhandbuch, 81 strony
StoreEver DAT Tape Drives Instrukcja Użytkownika   HP StoreEver DAT Tape Drives User Manual, 69 strony
StorageWorks 2.64 Core Switch Instrukcja Użytkownika   HP StorageWorks 2.64 Core Switch User Manual, 104 strony
StorageWorks Data Replication Manager Software Instrukcja Użytkownika   HP StorageWorks Data Replication Manager Software User Manual, 144 strony
StoreOnce Backup Instrukcja Użytkownika   HP StoreOnce Backup User Manual, 178 strony
XP7 Storage Instrukcja Użytkownika   HP XP7 Storage User Manual, 446 strony
3PAR StoreServ 7000 Storage Instrukcja Użytkownika   HP 3PAR StoreServ 7000 Storage User Manual, 59 strony
XP External Storage Software Instrukcja Użytkownika   HP XP External Storage Software User Manual, 138 strony
StorageWorks 1000 Modular Smart Array Instrukcja Użytkownika   HP StorageWorks 1000 Modular Smart Array User Manual, 52 strony
XP Cache LUN Software Instrukcja Użytkownika   HP XP Cache LUN Software User Manual, 20 strony
StorageWorks Auto Path VA Software Instrukcja Użytkownika   HP StorageWorks Auto Path VA Software User Manual, 70 strony
XP Performance Advisor Software Instrukcja Użytkownika   HP XP Performance Advisor Software User Manual, 159 strony